A standard cell-based assay to assess the function of murine CAR T cells, which we regularly perform at the end of the process of generating CAR T cells (see "Retroviral transduction of primary murine CD8 T cells").
Steps
Labeling target cells with 51Cr (day 0)
For each adherent tumor cell line, plate 5x105 cells / 3mL (previously growing in log phase) in one 6-well-plate well; Incubate cells for ~3hr to rest.
In the Hot Lab , label the target cells with 50 μL 51Cr (vial <1wk old), 100μL (1-2wk old), or 150μL (>2wk old). Place in Hot Lab incubator overnight.
Processing effector cells (day 1)
From each transduced T cell culture, remove 9x105 cells, wash with fresh mouse T cell media (mTCM) for 6min at 400rcf, and resuspend in 3mL mTCM.
In triplicates, transfer 150μL (4.5x104 effector cells) to U-bottom 96-well-plate wells (in columns 1, 2, 3). Pipet mTCM (100uL/wel) into the remainder of the row (4-12); prepare 3 serial dilutions (1:3) by pipetting 50uL to the respective 100uL volumes.
Example layout:
Begin processing the target cells. To remove extracellular 51Cr, briefly wash the adherent lines with 5mL Cell Dissociation Buffer (0.5mM EDTA in PBS). Repeat the wash. Dispose the 51Cr-containing media appropriately.
To dissociate target cells, add 3mL Cell Dissociation Buffer to each well, incubate at 37C for 10-15 mins. Add 3mL mTCM; centrifuge at 400rcf for 4min.
Count the cells using a hemocytometer. Adjust volume to 1E4 cells / mL mTCM.
Transfer 100μL (1E3 target cells) to each well on the respective half of the plate already containing 100uL of effector CAR-T cells.
Finally, transfer 100μL target cells to an extra row. Add 100μL of soap (NP40+Trypan blue) to generate a positive control. Add 100μL mTCM to generate a negative control.
Centrifuge plate at 800rpm for 3mins; incubate at 37C for 24 hours.
Reading scintillation plate
Harvest 30uL supernatant from each plate; carefully transfer onto respective Luma plate wells.
Dry the plate completely for ~24 hours.
Acquire data on the plate scintillation counter per respective protocol.